High-Pressure Gas Cylinder Requalification
(Compliant with KGS & DOT International Standards)
화인실텍 공인 검사장을 기반으로 하는 글로벌 재검사 서비스
High-Pressure Gas Cylinder Requalification
(Compliant with KGS & DOT International Standards)
화인실텍 공인 검사장을 기반으로 하는 글로벌 재검사 서비스
High-Pressure Gas Cylinder Requalification
(Compliant with KGS & DOT International Standards)
Global requalification services based on
certified inspection facilities
Global Cylinder Requalification Services Based on a KGS-Certified Inspection Facility
Compliance with safety and international regulations is essential worldwide.
Alvion Cyl Inc. provides global requalification services based on the official inspection facility of FineCylTec Co., Ltd., a KGS-accredited high-pressure gas cylinder requalification institution in Korea.
We support not only domestic KGS standards, but also U.S. DOT–compliant requalification for export and overseas operations.
Through this capability, Alvion Cyl delivers customized cylinder requalification services that meet a wide range of international standards for global customers.
1. KGS statutory requalification
2. DOT regulation–based requalification
3. Dual-standard requalification (KGS + DOT)
Alvion Cyl supports the requalification of cylinders subject to U.S. DOT regulations.
l DOT-Compliant
Requalification Support
(For Export & Overseas Operations)
Alvion Cyl supports the requalification of cylinders subject to U.S. DOT regulations.
• DOT-3A
• DOT-3AL
• DOT-SP 15647
• DOT-3AA
• DOT-4BW
• DOT-3AAX
• DOT-3T
All inspections are conducted on-site at FineCylTec’s facility, in accordance with Alvion Cyl’s international standards compliance and quality management system.
l Requalification Procedure
(Compliant with KGS & DOT
Standards)
l Issued Documents
• KGS Inspection Certificate
• DOT-Compliant Test Report
• Cylinder History & Data Traceability Report
What Sets Alvion Cyl’s Requalification Services Apart
• Simultaneous compliance with Korean KGS
and U.S. DOT standards
• Dual-certification–based requalification
services for overseas customers
• Direct utilization of FineCylTec’s KGS-
accredited inspection facility
• Advanced capabilities in hydrostatic testing,
leak testing, and internal/external inspections
• Support for a wide range of cylinder
specifications, including:
DOT-3AA, DOT-3AAX, DOT-3AL, DOT-3T,
DOT-SP15647, DOT-4BW, and composite
cylinders
• Full compliance with export and overseas
operational requirements, with issuance of
both Inspection Reports and DOT Technical
Reports
• Provision of documentation packages suitable
for international transportation and export
clearance
• One-stop services covering valve
replacement, hydrostatic testing, shot
blasting, marking, and condition improvement
• Seamless integration from repair and
inspection to final report issuance
l Requalification Standards
KGS Standards (Korea Gas Safety)
DOT 기준(미국 Department of Transportation)
알비온 씰은 해외 고객을 위해 DOT 시험 방식·마킹·
리포트까지 지원합니다.
l Scope of Requalification
Services
(Applicable to Both KGS & DOT Standards)
Seamless Cylinders
Welded Cylinders
l Cylinder Valves & Accessories
All accessories listed below are eligible for requalification or precision inspection.
• Medical oxygen cylinder valves compliant
with KS B 6214
• Air and oxygen cylinder accessories not
specified under Korean safety regulations
• Firefighting and fire-extinguishing cylinder
accessories
• Metal diaphragm valves for internal corrosion
resistance made of STS304 or equivalent
materials, compliant with KS D 3698
▼
The following inspections are performed in accordance with DOT requirements:
• Visual inspection
• Internal inspection / wall thickness
measurement
• Hydrostatic test / leak test
• Valve and accessory inspection
• Requalification marking\
• Issuance of technical reports
(DOT Test Report)
All inspections are conducted at the FineCyltec certified inspection facility under Alvion Cyl’s international standards compliance management system.
Is it time for your cylinder requalification?
Verify the current inspection status today.
Global Cylinder Requalification Services Based on a KGS-Certified Inspection Facility
Compliance with safety and international regulations is essential worldwide.
Alvion Cyl Inc. provides global requalification services based on the official inspection facility of
FineCylTec Co., Ltd., a KGS-accredited high-pressure gas cylinder requalification institution in Korea.
We support not only domestic KGS standards, but also U.S. DOT–compliant requalification
for export and overseas operations. Through this capability, Alvion Cyl delivers customized
cylinder requalification services that meet a wide range of international standards for global customers.
1. KGS statutory requalification
2. DOT regulation–based requalification
3. Dual-standard requalification (KGS + DOT)
Requalification Period for Cylinders and Specified Equipment
l DOT-Compliant Requalification Support
(For Export & Overseas Operations)
Alvion Cyl supports the requalification of cylinders subject to U.S. DOT regulations.
• DOT-3A
• DOT-3AL
• DOT-SP 15647
• DOT-3AA
• DOT-4BW
• DOT-3AAX
• DOT-3T
All inspections are conducted on-site at FineCylTec’s facility, in accordance with Alvion Cyl’s international standards compliance and quality management system.
l Requalification Procedure
(Compliant with KGS & DOT Standards)
l Issued Documents
• KGS Inspection Certificate
• DOT-Compliant Test Report
• Cylinder History & Data Traceability Report
What Sets Alvion Cyl’s Requalification Services Apart
• Simultaneous compliance with Korean KGS and U.S. DOT standards
• Dual-certification–based requalification services for overseas customers
• Direct utilization of FineCylTec’s KGS-accredited inspection facility
• Advanced capabilities in hydrostatic testing, leak testing, and internal/external inspections
• Support for a wide range of cylinder specifications, including:
DOT-3AA, DOT-3AAX, DOT-3AL, DOT-3T, DOT-SP15647, DOT-4BW, and composite cylinders
• Full compliance with export and overseas operational requirements, with issuance of both Inspection Reports and DOT Technical Reports
• Provision of documentation packages suitable for international transportation and export clearance
• One-stop services covering valve replacement, hydrostatic testing, shot blasting, marking, and condition improvement
• Seamless integration from repair and inspection to final report issuance
l Requalification Standards
KGS Standards (Korea Gas Safety)
DOT Requalification Standards (U.S. Department of Transportation (DOT)
Alvion Cyl supports DOT testing, marking, and report issuance for overseas customers.
l Scope of Requalification Services
(Applicable to Both KGS & DOT Standards)
Seamless Cylinders
Welded Cylinders
l Cylinder Valves & Accessories
All accessories listed below are eligible for requalification or precision inspection.
• Medical oxygen cylinder valves compliant with KS B 6214
• Air and oxygen cylinder accessories not specified under Korean safety regulations
• Firefighting and fire-extinguishing cylinder accessories
• Metal diaphragm valves for internal corrosion resistance made of STS304 or equivalent materials, compliant with KS D 3698
▼
The following inspections are performed in accordance with DOT requirements:
• Visual inspection
• Internal inspection / wall thickness measurement
• Hydrostatic test / leak test
• Valve and accessory inspection
• Requalification marking
• Issuance of technical reports (DOT Test Report)
All inspections are conducted at the FineCyltec certified inspection facility under Alvion Cyl’s international standards compliance management system.
Is it time for your cylinder requalification?
Verify the current inspection status today.
President: Ji Ho Choi
Business Registration Number:
231-86-03338
Address: 3F, 784-100 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Republic of Korea
Family website
Copyright Alvion Cyl Inc. All rights reserved.
President: Ji Ho Choi
Business Registration Number: 231-86-03338
Address: 3F, 784-100 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Republic of Korea
Copyright Alvion Cyl Inc. All rights reserved.